To attach a cable to the Ethernet management port, follow these steps: Step 1 Connect the RJ-45 plug at one end of the network cable to the target device port. The lug supports up to 6 AWG wire. Installing the Chassis in the Rack (bottom view) shows how to install a chassis in a rack when the chassis has the rack-mount brackets attached at the rear of the chassis. Table 2 Brug erklringsnummeret efter hver advarsel for at finde oversttelsen i de oversatte advarsler, der fulgte med denne enhed. Configuration Set Up the Video Integration in Control Hub. Step 3 While one person holds the chassis in place, secure the chassis to the rack with the four 10-32 x 3/4-inch or the four 12-24 x 3/4-inch Phillips-head machine screws (two on each side) that are supplied in the accessory kit. Commercial building is subjected to direct lightning strikes. To reduce the possibility of EMI and RFI, follow these guidelines: When wires are run for any significant distance in an electromagnetic field, interference can occur between the field and the signals on the wires. The RSS feeds are a free service. Table 3 Catalyst 4500-X Series Switch Rear Panel Feature Descriptions. The Ethernet management port provides out-of-band management, which enables you to use the CLI interface to manage the switch by its IP address. You have completed the initial configuration of the switch, and the switch displays its configuration. USB Type A interface (top connector) provides access to an external USB FLASH device (also known as a thumb drive or a USB key). Table 1 Both sizes of screws are supplied in the accessory kit. Figure 6 Removing the Standard Rack-Mount Brackets From the Chassis. Systems are especially sensitive to variations in voltage supplied by the AC power source. To install the chassis in the rack, follow these steps: Step 1 Have one person carefully lift and position the chassis in the rack so that the rack-mount bracket flanges are in contact with the rack posts and the chassis is level. Step 6 (Optional) Configure the Simple Network Management Protocol (SNMP) by responding to the prompts. To set up the switch, you need to complete the setup program, which runs automatically after the switch is powered on. Route the system ground wire to ensure that it does not interfere with other switch hardware or rack equipment. The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, allows spaces, but ignores leading spaces. This moisture can cause corrosion of internal components and degradation of properties such as electrical resistance, thermal conductivity, physical strength, and size. Ensure that the ventilation system in a closed rack does not prevent cooling by creating negative pressure around the chassis and redirecting the air away from the chassis intake vent. Whats New in Cisco Product Documentation Xfire video game news covers all the biggest daily gaming headlines. To protect against these types of problems, power cables should always be properly grounded. A console serial port (RJ-45 connector) is provided for switch management using standard console equipment. To install either the 19-inch or the 23-inch center rack-mount kit on the Catalyst 4500-X chassis, follow these steps: Step 1 Place the switch chassis on an antistatic work surface. c. Click Go. The product has been exposed to water or other liquids. Ce symbole d'avertissement indique un danger. as an RSS feed and set content to be delivered directly to your desktop using a reader application. The following tools are needed to install the chassis in the rack: Note The torque wrench must be properly calibrated to ensure that correct torque values are applied to the installation screws. Step 3 Secure the rack-mount bracket to the chassis with four M4 x 6 mm Phillips flat-head screws. This information is also needed to use the device manager or Cisco Network Assistant to configure and manage the switch. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Procedures for cabling source DC to the DC-input power supply are contained in the The interface supports the 4-GB Cisco USB flash drive (Cisco part no. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Commercial building is located in an area where lightning storms frequently occur but is not subject to direct lightning strikes. WebUser: I am using purity as my theme.Whenever I want to log out, I get the message that PurityM isn't installed or needs to be updated. Shipped as part of the Catalyst 4500-X chassis accessory kit. Release Notes for the Catalyst 4500 Series Switch, Release IOS XE 3.3.0SG(15.1(1)SG). Este smbolo de aviso significa perigo. This situation can cause overtemperature conditions in the chassis at or near the top of the rack. As the chassis powers up, you can monitor the progress by watching the LEDs located on the front panel of the chassis, the front panel of the fan tray (located at the back of the chassis), and the front panel of the power supplies (located at the back of the chassis) as follows: Once the chassis has completed the power up cycle (STATUS LED is green), you are ready to perform a configuration of the chassis. Step 3 Crimp the ground wire in the barrel of the ground lug. The product has been dropped or shows signs of damage. Conversely, RFI from high-power telephones can cause spurious characters to appear on the system monitor. Cage nuts are not supplied as part of the accessory kit. Chassis installations that rely only on the AC third-prong ground are insufficient to properly and adequately ground the systems. (See Figure 8.) WebSearch Common Platform Enumerations (CPE) This search engine can perform a keyword search, or a CPE Name search. (International)Circuits should be sized according to local and national codes. C4KX-NM-8SFP+) that can be installed in the chassis. The typical connection to the Management Ethernet port uses an Ethernet cable with RJ-45 connectors at each end. Du er i en situasjon som kan fre til skade p person. The secret password is encrypted, and the enable password is in plain text. Observe the following guidelines: Failure to observe these guidelines can damage internal chassis components. Catalyst 4500-X DC-Input Power Supply Installation Note Step 11 While one person holds the chassis in place, secure the chassis to the equipment rack posts with either the four 10-32 x 3/4-inch or the four 12-24 x 3/4-inch Phillips-head machine screws (two on each side). U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Set the screws and the brackets aside. This section provides the basic guidelines for connecting the Catalyst 4500-X series switch DC-input power supplies to the site power source: When running power and data cables together in overhead cable trays or subfloor cable trays, be aware of the following caution: Also be aware of the following caution concerning the use of Category 5e and Category 6 Ethernet cables: Table 7 Place the black conductive loop over your wrist and tighten the strap so that it makes good contact with your bare skin. Besides these appliances, the greatest threats to a system power supply are surges or blackouts that are caused by electrical storms. Step 6 Prepare the other end of the ground wire and connect it to an appropriate earth ground point in your site to ensure adequate earth ground for the switch. However, fans also ingest dust and other particulates, causing contaminant buildup on the fan blades and in the system, which create a thermal blanket on components increasing the internal chassis temperature. to display the setup prompt. Note Some equipment racks have a power strip along the length of one of the rear posts. Catalyst 4500-X DC-Input Power Supply Installation Note. AmberSolid (not flashing); either a minor alarm was detected in the system or the system is booting and awaiting Power-on self-test (POST). Step 6 Install the chassis in the four-post rack as follows: a. Step 5 Slide the two slider brackets into the chassis attach brackets. , the switch appears as a candidate switch in the Network Assistant GUI. Catalyst 4500-X AC-Input Power Supply Installation Note. Step 5. Otherwise, assess the condition of the victim, and then call for help. If the ambient intake air temperature exceeds 104F (40C), the system might experience minor temperature alarms and is in danger of overheating. You are in a situation that could cause bodily injury. Table 2 Catalyst 4500-X Series Switch Front Panel Feature Descriptions. Sie befinden sich in einer Situation, die zu Verletzungen fhren kann. Two plastic cable guides are provided as part of the accessory kit. All connections must be removed to de-energize the unit. FOX FILES combines in-depth news reporting from a variety of Fox News on-air talent. Cisco Room Kit EQ Cisco Webex Room 70 Single with Floor Stand Installation Guide (PDF - 4 MB) View all documentation of this type. The keyword search will perform searching across all components of the CPE name for the user specified search text. Figure 14 Ethernet Management Cable Connection. Cisco Room Kit EQ At-a-Glance Brochure ; Cisco Webex Room Phone At-a-Glance ; Data Sheets. ), 20 lb (9.07 kg) (without power supplies) The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores leading spaces. Anvnd det nummer som finns i slutet av varje varning fr att hitta dess versttning i de versatta skerhetsvarningar som medfljer denna anordning. LED that provides operational status of the fan assemblies. You need to purchase a mount kit. Then used phone app LTE Discovery and with a ladder located the spot with the strongest signal at roof level. WebWith the right servers, storage and technologies, you can apply a zero-trust approach to protect against breaches, keep data private across hybrid ecosystems and unify data protection with cyber resilience. (C4KX-PWR-750DC-R= and C4KX-PWR-750DC-F=), Fan assembly Step 4 Attach the left and right brackets to the rear of the switch chassis using eight M4 Phillips-head screws (four on each side) provided in the rack-mount kit. , which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html. Failure to maintain adequate spacing between chassis can cause the switch chassis that is drawing in the hot exhaust air to overheat and fail. Step 2 Connect the RJ-45 plug at the other end of the network cable to the Ethernet Management port on the Catalyst 4500-X chassis. Without proper and complete system grounding, you run the risk of increased component damage due to ESD. If you use twisted-pair cable in your plant wiring with a good distribution of grounding conductors, the plant wiring is unlikely to emit radio interference. (C4KX-FAN-R= and C4KX-FAN-F=), 2.25 x 7.00 x 8.50 in WebLarge sharing icon on second screen. For example, some places in the United States, such as Florida, are subject to more lightning strikes than other areas. Cisco SFP and SFP+ Transceiver Modules Installation Notes See the product data sheet for further information. b. The center rack-mount brackets are reversible; they can be installed either on the front sides of the chassis or on the rear sides of the chassis. Step 4 Open your center rack-mount kit and verify the contents. at this URL: http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/installation/note/78_15160.html. However, if a system is located in an unusually humid location, a dehumidifier can be used to maintain the humidity within an acceptable range. Using a torque wrench, tighten the eight screws to between 8 inch-lbs and 10 inch-lbs (0.90 Newton-meters to 1.13 Newton-meters). To read the Cisco Information Packet, follow these steps: a. Click the Information Packet Number field, and make sure that the part number 78-5235-03B0 is highlighted. at this URL: For SFP and SFP+ transceiver installation instructions, see the 24 lb (10.89 kg) (with two power supplies installed), (32-port chassis equipped with 5 fan assemblies. New California laws will create 4 million jobs, reduce the states oil use by 91%, cut air pollution by 60%, protect communities from oil drilling, and accelerate the states transition to clean Existe riesgo para su integridad fsica. Follow the steps in the Configuring the Setup Program section. High-humidity conditions can cause moisture migration and penetration into the system. The electromagnetic pulse caused by lightning or other high-energy phenomena can easily couple enough energy into unshielded conductors to destroy electronic devices. . Codec Pro Installation Guide. C4KX-NM-BLANK) installed over the network uplink module bay. Make meetings dynamic and engaging for all with Yamaha's CS-800 Video Sound Bar and CS-500 Video Collaboration System. Statement 1024. If the rack is mobile, you can push it back within 1 foot (30.45 cm) of a wall or cabinet for normal operation and pull it out when necessary for maintenance. Note The chassis supports all combinations of AC-input and DC-input power supplies: two AC-input power supplies, two DC-input power supplies, or one AC-input power supply and one DC-input power supply. Measure from the outside of the front mounting posts to the outside of the rear mounting strip. Room Kit Pro Precision 60 Installation Guide. Contains instructions on how to configure the Catalyst 4500-X switch. Install the chassis in an enclosed rack only if it has adequate ventilation or an exhaust fan; use an open rack whenever possible. Use o nmero da declarao fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham o dispositivo. Figure 7 Installing the Center Rack-Mount Brackets on the Chassis (23-Inch Rack-Mount Brackets Shown). Ensure that cables from other equipment will not obstruct the airflow through the chassis or impair access to the power supplies or switching modules. Al final de cada advertencia encontrar el nmero que le ayudar a encontrar el texto traducido en el apartado de traducciones que acompaa a este dispositivo. . Statement 1072. Cisco Webex Room Kit Plus PTZ 4K Installation Guide (PDF - 1 MB) Cisco TelePresence Desk, MX, SX, and Room Series and Webex Boards Getting Started Guide (CE9.15) 08-Feb-2021 (PDF - 3 MB) Cisco TelePresence DX, MX, SX, and Room Series and Webex Boards Getting Started Guide (CE9.14) 28-Oct-2020 (PDF - 3 MB) Table 8 Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos eltricos e familiarize-se com as prticas padro de preveno de acidentes. b. Run the command Install-Module MicrosoftTeams -AllowClobber, and confirm with Y command, in order to attempt the regular installation process. This warning symbol means danger. Step 2 Enter a hostname for the switch, and press Return. Catalyst 4500-X Series Switch, Chassis dimensions (all six chassis models), 1.75 x 17.25 x 21 in. Also contains descriptions of the supported AC power cords. Also includes language translations of the warnings that appear in the other Catalyst 4500-X documentation. b. If your chassis does not have the uplink module installed, you must have a blank uplink module cover (part no. Each system is rated to operate at 8 to 80 percent relative humidity, with a humidity gradation of 10 percent per hour. The IP address and subnet masks shown are examples. Make sure the line of sight is clear as possible from tree branches, buildings, etc. WebCisco Webex Codec Plus and Room Kit Plus Precision 60 Installation Guide (PDF - 1 MB) Cisco Webex PTZ 4K Ceiling Mount Installation Guide (PDF - 724 KB) Cisco Webex PTZ 4K Wall Bracket Installation Guide (PDF - 465 KB) Cisco Webex Quad Camera Cable Cover Installation Guide (PDF - 593 KB) Cisco Webex Room Kit Plus Installation For SFP/SFP+ transceiver installation instructions, see the . Prolonged operation at a temperature in excess of 104F (40C) might severely affect the long-term reliability of the equipment. An additional 8 ports of 1000BASE-X (SFP) or 10GBASE-X (SFP+) are available in a removable Ethernet uplink module that mounts in a bay on the front of the switch chassis. Codec Pro Wall Bracket Installation Guide. Este smbolo de aviso significa perigo. The Catalyst 4500-X series switch supports either one or two DC-input power supplies in bays at the back of the chassis. Radio frequencies emanating from a system can also interfere with cordless and low-power telephones. Determine source and cause of noise if possible, and mitigate as closely as possible at the noise source or reduce coupling from the noise source to the victim equipment. Proper grounding practices ensure that the buildings and the installed equipment within them have low-impedance connections and low-voltage differentials between chassis. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Auditorium. The Wait is Over. To maintain proper air circulation through the switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis hot air exhaust. (C4KX-PWR-750AC-R= and C4KX-PWR-750AC-F=), 4.38 x 7.13 x 20.13 in Warning This equipment must be grounded. Place the chassis on the floor or on a sturdy table as close as possible to the rack. Leaving the system on may cause problems when the power is restored; all other appliances left on in the area can create large voltage spikes that can damage the system. If you enter at this URL: http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6974.html. After you install the system ground lug, follow these steps to correctly attach the ESD wrist strap: Step 1 Attach the ESD wrist strap to bare skin as follows: a. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. lists the rack mount kits that are available for use with the Catalyst 4500-X series switch chassis. La situazione potrebbe causare infortuni alle persone. (See Figure 5.). When working on electrical equipment, follow these guidelines: Use extreme caution; do not become a victim yourself. (H x W x D), WS-C4500X-16SFP+ and WS-C4500X-F-16SFP+ These tests have been conducted in earthquake environment and criteria, office vibration and criteria, transportation vibration and criteria, and packaged equipment shock. (See Figure 2.) Whenever possible, turn off the system and any peripherals, and unplug them from their power sources during thunderstorms. (7.62 x 25.40 x 37.80 cm). Note Depending on your configuration, you might not need to install all of the cables described in the following sections. Ennen kuin ksittelet laitteistoa, huomioi shkpiirien ksittelemiseen liittyvt riskit ja tutustu onnettomuuksien yleisiin ehkisytapoihin. Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix Chassis dimensions, weights, and packaging specifications for the Catalyst 4500-X series switch are listed in 2.Chassis weights can vary slightly based on the configuration. Once the power cord is connected between the AC-input power supply and source AC and source AC is on, the power supply immediately powers up. Configuration Examples and TechNotes. Cisco Room Kit EQ At-a-Glance Brochure ; Cisco Webex Room Phone At-a-Glance ; Data Sheets. If you are using bare wire, go to Step 2. c. Align the mounting holes in the front and rear rack-mount brackets with the mounting holes in the equipment rack posts. Note This rack-mount kit is supplied as part of the Catalyst 4500-X series switch accessory kit. Note The 16 port version of the chassis does not have the block of 16 ports on the right side of the front panel. Figure 8 Mounting the Chassis in the Equipment Rack Using the Center Rack-Mount Kit (23-Inch Rack-Mount Kit Shown). Step 5 Enter a virtual terminal (Telnet) password, and press Return. b. Safety warnings appear throughout this publication in procedures that may harm you if performed incorrectly. Introducing: Yamaha's Video Collaboration Systems. Configuration Examples and TechNotes. To install the Catalyst 4500-X series switch in a four-post rack using the optional C4948E-BKT-KIT= rack-mount kit, follow these steps: Although the metal carrier helps to protect the board from ESD, always use an ESD grounding strap when handling modules. Turvallisuusvaroitusten knnkset lytyvt laitteen mukana toimitettujen knnettyjen turvallisuusvaroitusten joukosta varoitusten lopussa nkyvien lausuntonumeroiden avulla. Mounting the Chassis in the Equipment Rack Using the Center Rack-Mount Kit (23-Inch Rack-Mount Kit Shown) (bottom view) shows how to install a chassis in a rack when the chassis has the center rack-mount brackets attached at the rear of the chassis. *** Pricing upon request. Table 4 Chassis Dimensions, Weights and Packaging Specifications for the To mount your AP on a drop ceiling T-rail, use the included drop ceiling mounting accessory kit. Use this rack mount kit when you are installing the switch in a 19 inch (48.3 cm), 2-post rack. Cisco Webex Room Kit Installation Guide (PDF - 1 MB) Cisco TelePresence DX, MX, SX and Room Series Getting Started Guide (CE9.5) 27-Sep-2018 (PDF - 1 MB) Cisco TelePresence DX, MX, SX and Room Series Getting Started Guide (CE9.4) 28-Jun-2018 (PDF - 2 MB) Figure 9 Installing the Optional Cable Guide to the Center Rack-Mount Bracket. 21 lb (9.53 kg) (with one power supply installed) Prop 30 is supported by a coalition including CalFire Firefighters, the American Lung Association, environmental organizations, electrical workers and businesses that want to improve Californias air quality by fighting and preventing wildfires and reducing air pollution from vehicles. Step 2 If the standard rack-mount brackets are attached to the chassis, you must remove them by loosening and removing the eight M4 screws (four on each side) that secure the standard rack-mount brackets to the chassis sides. Step 8 Repeat Step 6 and Step 7 for the second bracket. Note The DC-input power supply is not supplied as part of the standard chassis configuration. Featuring Yamaha's SoundCap Eye technology, the newly-developed hexa This installation has a history of malfunction due to electromagnetic noise. Cisco Webex Room Bar Installation Guide (PDF - 12 MB) Cisco TelePresence Desk, MX, SX, and Room Series and Webex Boards Getting Started Guide (CE9.15) Cisco TelePresence DX, MX, SX and Room Kit Series Getting Started Guide (CE9.1) (PDF - 1 MB) View all documentation of this type. CAB-CON-C4K-RJ45) can be ordered as an option. Shipping box dimensions and packaged shipping weights for the replaceable assemblies on the Catalyst 4500-X switch are provided in Step 8 Configure the interface by entering the switch IP address and subnet mask and pressing Return. Step 2 Adjust the chassis up or down in the rack until two screw holes in each rack-mount bracket flange are aligned with mounting holes in the equipment rack post. The 10/100/1000 Ethernet Management port can be used to manage the switch through an Ethernet network. 2022 Cisco and/or its affiliates. 1.Power supplies, either AC-input or DC-input, are not included in the basic configuration; they are ordered separately. Bruk nummeret i slutten av hver advarsel for finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. In chassis equipped with redundant power supplies, it is recommended that you connect the power supplies to separate source AC circuits to prevent the chassis from shutting down in the event that one source AC circuit fails. You can boot the switch from the USB drive. Before rack-mounting the switch, ensure the following: Install heavier equipment in the lower half of the rack to maintain a low center of gravity and prevent the rack from becoming top-heavy and tipping over. The main purpose of the beacon LED is to enable identification from a remote location during configuration or troubleshooting. Statement 1017, Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Existing commercial building is not subject to natural environmental noise or man-made industrial noise. C4KX-NM-8SFP+) (Included as part of the WS-C4500X-24ES and WS-C4500X-40ES chassis; available as an optional upgrade on the other Catalyst 4500-X series chassis). This is an optional rack-mount kit that can be ordered separately. at this URL: http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6981.html. If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Avant de travailler sur un quipement, soyez conscient des dangers lis aux circuits lectriques et familiarisez-vous avec les procdures couramment utilises pour viter les accidents. If the difference between the measured intake air temperature and the exhaust air temperature does not exceed 10C, there is sufficient airflow in the rack. Ethernet ports require either an SFP or an SFP+ transceiver to operate. No uplink module. They offer: Simple: Cisco Business 110 Series switches work right out of the box, with plug-and-play capability without software installation and configuration. Dieses Warnsymbol bedeutet Gefahr. ft. with wifi and supports wifi speeds up to 900 Mbps. You must assign an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet. Regulatory Compliance and Safety Information for the Catalyst 4500-X Series Switch. If necessary, operate the chassis with the rack open. The uplink module ports require that either SFP or SFP+ transceivers be installed to operate. WebThe latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing ), Shipping package dimensions (all six chassis models), 5.75 x 21.13 x 28.63 in. Figure 14 shows a typical Ethernet management connection between the switch and a PC. Este smbolo de aviso indica peligro. -n F (40 The Federal Communications Commission (FCC) publishes specific regulations to limit the amount of EMI and RFI emitted by computing equipment. Locate the end of the wrist strap that attaches to your body and secure it to your bare skin. C4KX-PWR-BLANK=) installed over the empty power supply bay to maintain proper airflow through the chassis. Tilanne voi aiheuttaa ruumiillisia vammoja. All rights reserved. Table 4 Grounding best practices must be closely followed. Cisco Room Kit EQ Cisco Webex Room 55 with Floor Stand Installation Guide (PDF - 1 MB) View all documentation of this type. Note The DC-input power supply does not have a power switch. Step 6 Position one of the brackets against the side of the chassis with the brackets four mounting holes aligned with the mounting holes in the chassis as shown in Figure 7. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen. Select the language in which you would like to read the document. Note In Installing the Rack-Mount Brackets, the top view shows the rack-mount brackets being attached to the front sides of the chassis. SAY GOODBYE TO DEAD SPOTS AND BUFFERING - Our TrueMesh technology intelligently routes traffic to reduce drop-offs so you can confidently stream 4K video, game, and video conference. Conductors carrying lightning current should be spaced away from power and data lines in accordance with applicable recommendations and codes. If you previously have had similar problems, you might want to consult experts in electrical surge suppression and shielding. Operating a system at high altitude (low pressure) reduces the efficiency of forced and convection cooling and can result in electrical problems related to arcing and corona effects. If the difference in air temperature exceeds 10C, there is insufficient airflow to cool the chassis. Create virtual conference rooms tailor-made to support communication and collaboration remotely via Lifesize Cloud. A bicolor port link status LED that is associated with each Ethernet port. Step 2 Grasp the spring or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal spot (unpainted surface) on the rack. Cisco Webex Room Kit Mini and Webex on Flip Installation Guide (PDF - 5 MB) Cisco TelePresence DX, MX, SX and Room Series Getting Started Guide (CE9.5) 27-Sep-2018 (PDF - 1 MB) Cisco TelePresence DX, MX, SX and Room Series Getting Started Guide (CE9.4) 28-Jun-2018 (PDF - 2 MB) Questo simbolo di avvertenza indica un pericolo. A combination push button switch and LED indicator. You should place the antenna as high as possible and point it towards the tower. WebIntel's innovation in cloud computing, data center, Internet of Things, and PC solutions is powering the smart and connected digital world we live in. Step 7 Enter the interface name (physical interface or VLAN name) of the interface that connects to the management network, and press C). Modules consist of printed circuit boards that are fixed in metal carriers. Once the cabling is complete between the power supply and source DC and the source DC breaker is turned on, the power supply immediately powers up. This installation note contains the following sections: The Catalyst 4500-X series switch is a 1RU unit that provides either 16 or 32 10GBASE-X (SFP+) or 1GBASE-X (SFP) ports. In storage, a system can withstand from 5 to 95 percent relative humidity. Voc est em uma situao que poder ser causadora de leses corporais. The situation is as followed:our users use HP laptop (elitebook) connected to a HP USB-C replicator G2 with one ore sometimes two monitors on the desk and a roomkit with large screen on the wall. Multi-color LED that provides status of the system. at the following two prompts. USB-X45-4GB-E). Dette advarselssymbol betyder fare. For an up-to-date list of which SFP transceivers are supported, see the WebPassword requirements: 6 to 30 characters long; ASCII characters only (characters found on a standard US keyboard); must contain at least 4 different symbols; Step 2 Position one of the rack-mount brackets against one side of the chassis, and align the four countersunk screw holes with the four M4 holes in the chassis. The bottom view shows the rack-mount brackets being attached to the rear sides of the chassis. Step 2 Insert the stripped end of the ground wire into the open end of the ground lug. Configuration. The program, frequently a PC application, such as HyperTerminal or ProcommPlus, makes communication between the switch and your PC or terminal possible. Room Kit Pro Installation Guide. This is an optional rack-mount kit that can be ordered separately. Fr du begynner arbeide med noe av utstyret, m du vre oppmerksom p farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for forhindre ulykker. Extreme moisture buildup inside the system can result in electrical shorts, which can cause serious damage to the system. The second, unused, power supply bay must have a power supply blank panel (part no. Power supplies must be ordered separately. Each system meets these FCC regulations. Antes de iniciar a utilizao de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos eltricos e familiarize-se com as prticas habituais de preveno de acidentes. WebThe Atlona AT-USB-EX100-KIT is a high speed USB extender kit. The C4948E-BKT-KIT= kit is used with the standard rack-mount brackets and attachment hardware supplied as part of the Catalyst 4500-X switch accessory kit to install the chassis in a four-post rack. Buildings in which climate is controlled by air-conditioning in the warmer months and by heat during the colder months usually maintain an acceptable level of humidity for system equipment. If the switch is installed in a closed or multiunit rack assembly, the ambient operating temperature of the rack environment might be higher than the ambient room temperature. Table 7 Catalyst 4500-X Series Switch Rack Mount Kits. 19 inch wide, 2-post center rack-mount kit. The product does not operate correctly when you follow the operating instructions. Step 3 Repeat Steps 1 and 2 to install the second cable guide, if needed. WebOur Commitment to Anti-Discrimination. Contains the regulatory compliance and safety information for the Catalyst 4500-X series switch chassis. 22 lb (9.98 kg) (with one power supply installed) Note A console port cable is not provided as part of the accessory kit. ), (32-port chassis equipped with an 8-port uplink module and 5 fan assemblies. Also, place the system on a dedicated power circuit (rather than sharing a circuit with other heavy electrical equipment). (See Figure 2.) WebThe Cisco Room Kit Plus features Codec Plus and the intelligent Quad Camera bar to enable video collaboration in large meeting spaces by simply connecting it with external microphones and up to two screens. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Figure 2 shows the rear of the switch chassis and identifies the major features. Whats New in Cisco Product Documentation Table 1 Catalyst 4500-X Series Switch Models. . Existing commercial building is not subject to natural environmental noise or man-made industrial noise. The documentation set for this product strives to use bias-free language. Join the discussion about your favorite team! You can also configure SNMP later through the CLI, the device manager, or the Network Assistant application. DePaul University does not discriminate on the basis of race, color, ethnicity, religion, sex, gender, gender identity, sexual orientation, national origin, age, marital status, pregnancy, parental status, family relationship status, physical or mental disability, military status, genetic information or other status protected Step 9 To configure SNMP later, enter Cisco SFP and SFP+ Transceiver Module Installation Notes Catalyst 4500 Series Switch Cisco IOS Command Reference, Release IOS XE 3.3.0SG(15.1(1)SG). Place a level on top of the chassis and verify that the chassis is not tilted in the equipment rack. VIEW ALL WORKSPACES. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. The AT-USB-EX100-KIT is ideal for popular conferencing applications such as Zoom and Microsoft Teams , where USB components including laptops, cameras, Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Dette advarselssymbolet betyr fare. To connect the RJ-45 console port, follow these steps: Step 1 Connect an RJ-45-to-DB-9 adapter cable to the 9-pin serial port on the PC. Get started for free. C4KX-PWR-BLANK=) installed to maintain air circulation through the chassis and to maintain EMI integrity. Cisco Webex Room Kit Pro PTZ 4K Installation Guide (PDF - 1 MB) Cisco TelePresence Desk, MX, SX, and Room Series and Webex Boards Getting Started Guide (CE9.15) 08-Feb-2021 (PDF - 3 MB) Cisco TelePresence DX, MX, SX, and Room Series and Webex Boards Getting Started Guide (CE9.14) 28-Oct-2020 (PDF - 3 MB) See the Software Configuration Guide for detailed procedures on how to configure your system. Note Support restrictions for the SFP-10G-ZR SFP+ transceiver on a Catalyst 4500-X switch include: For an up-to-date list of which SFP transceivers are supported, see the (5.72 x 17.78 x 21.59 cm), 3.00 x 10.00 x 14.88 in Figure 1 Catalyst 4500-X Series Switch Chassis Features (Front View; 32-Port Chassis Shown), USB ports (2 ports) Top port is a Type A connector; bottom port is a Type B connector. For an up-to-date list of which SFP+ transceivers are supported, refer to the For exact measurements of your device, take a look at the CAD drawings: Quad Camera, PDF version. When preparing your site for the switch installation, follow these general requirements: Warning This product relies on the buildings installation for short-circuit (overcurrent) protection. You need this information from your network administrator: To complete the setup program and an initial configuration for the switch, follow these steps: Step 1 Enter for a list and descriptions of the AC power cords supported by the Catalyst 4500-X switch AC-input power supply. Contains instructions for installing and removing the optional 8-port network uplink module in the Catalyst 4500-X chassis. Contains the latest software caveats and workarounds related to the Catalyst 4500-X switch. This fact has two implications for the construction of plant wiring: Note To predict and remedy strong EMI, you may also need to consult experts in radio frequency interference (RFI). Get the latest science news and technology news, read tech reviews and more at ABC News. A blue LED is located on the chassis rear panel to aid in the identification of a particular chassis by the operator. Any constraints placed on the free flow of air through the chassis or an elevated ambient air temperature can cause the switch to overheat and shut down. Step 2 Start the terminal emulation program on the PC or the terminal. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen, die zusammen mit diesem Gert ausgeliefert wurden. After you complete the setup program, the switch can run the default configuration that you created. To install the Catalyst 4500-X series switch in a four-post rack using the optional C4948E-BKT-KIT= rack-mount kit, follow these steps: a. Fans cool the power supplies and the system components by drawing in room temperature air, circulating the air through the power supplies and the chassis, and exhausting the heated air out through various openings in the chassis. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. Using a torque wrench, tighten the four screws to between 8 inch-lbs and 10 inch-lbs (0.90 Newton-meters to 1.13 Newton-meters). Additionally, there restrictions on when you can use the SFP-10G-ZR SFP+ transceiver on the Catalyst 4500-X series switch. no Note If the equipment rack post-mounting holes are not threaded, you must obtain the proper size cage-nuts to secure the center rack-mount mounting screws to the rack. The underbanked represented 14% of U.S. households, or 18. This document covers the installation process for the Catalyst 4500-X series switch chassis. Standard 19 inch wide, 2-post front rack-mount kit. To prevent corrosion, avoid touching contacts on boards and cards, and protect the system from extreme temperatures and moist, salty environments. The Cisco IOS software provides standard file system access to the flash device: read, write, erase, and copy, as well as formatting of the flash device with a FAT file system. The Catalyst 4500-X switch chassis supports either one or two AC-input power supplies in bays located at the back of the chassis. Note The AC-input power supply does not have a power switch. It supports extension of USB 2.0 data up to 330 feet (100 meters) using a single, cost effective Category-type twisted pair cable. If you are using the ESD wrist strap supplied with the FRUs, open the wrist strap package and unwrap the ESD wrist strap. as that interface. Then mount the outside antenna. C4KX-NM-BLANK=) installed over the empty uplink module bay to maintain proper airflow through the chassis. lists the documentation supporting the Catalyst 4500-X series switch that is available on http://www.cisco.com. Note If the chassis is mounted to the rear posts of the equipment rack, the cable guides cannot be installed. Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action. Denna varningssignal signalerar fara. Cage-nuts are not supplied as part of the accessory kit. For Ethernet management port configuration information, see the software configuration guide at this URL: http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/15.1/XE_330SG/configuration/guide/sw_int.html#wp1110617. If the uplink module is not installed, you must have a blank panel (part no. If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel. Each fan assembly has an LED associated with it providing fan status. But I still get the same message every time I try to log out. Universal ID (UID) beacon. Ground lug screwsTwo M4 x 8 mm pan-head screws. Step 1. Contains descriptions of all of the software commands available that support the Catalyst 4500-X switch. WebOur video conferencing solutions allow you to upgrade your conference room to support video calls from Microsoft Teams , Zoom , Cisco Webex , Google Meet, and more. Note Individual power supply status is also available through two LEDs mounted on each power supply at the back of the chassis. Contains instructions for removing and installing the AC-input power supply in the Catalyst 4500-X switch chassis. To install the rack-mount brackets on the front sides of the chassis, follow these steps: Step 1 Remove the two rack-mount brackets and eight M4 x 6 mm Phillips flat-head screws from the accessory kit. Overvoltage, undervoltage, and transients (or spikes) can erase data from memory or even cause components to fail. If your chassis is equipped with only one power supply (either AC-input or DC-input), you must have a blank power supply cover (part no. See the Step 3 Configure the baud rate and character format of the PC or terminal to match the console port characteristics: Step 4 The PC or terminal displays the bootloader sequence. The kit contains: Drop ceiling mounting clips with set screws . Return CAD Drawings. Electromagnetic interference (EMI) and radio frequency interference (RFI) from a system can adversely affect devices such as radio and television (TV) receivers operating near the system. c. Measure the space between the inner edges of the left front and right front mounting posts to ensure that it is 17.75 inches (45.09 cm) wide. Claim your free 20GB now The accessory kit can be used to mount to most 9/16, 15/16 or 1 T-rails. Antes de manipular cualquier equipo, considere los riesgos de la corriente elctrica y familiarcese con los procedimientos estndar de prevencin de accidentes. Step 4 Place the ground wire lug against the system ground pad located on the rear panel of the chassis (see Figure 2), making sure that there is solid metal-to-metal contact. (See Figure 6.) Step 5 Secure the ground lug to the chassis with the two M4 screws supplied in the accessory kit. Table 8 Documentation Supporting the Catalyst 4500-X Series Switch, Catalyst 4500-X 8-Port Network Uplink Module Installation Note. Note The 10C temperature differential between the intake and the exhaust must be determined by taking measurements using external digital temperature probes. The power supplies are ordered separately. Each system is rated to operate at altitudes from 50 to 6500 feet (16 to 1981 meters) and can be stored at altitudes of 50 to 35,000 feet (16 to 10,668 meters). Pressing the blue beacon LED switch toggles the beacon LED on and off. Yes We recommend that you install a NEBS-compliant system ground as part of the chassis installation process. Subscribe to the (See Figure 3, top view.) Figure 4 Installing the Chassis in the Rack. Du befinder dig i en situation med risiko for legemesbeskadigelse. When you include NEBS-compliant system grounds, you reduce or prevent shock hazards, greatly reduce the chances of equipment damage due to transients, and substantially reduce the potential for data corruption. However, the chassis can operate for an indefinite period of time with only four fans running. A clean operating environment can greatly reduce the negative effects of dust and other particulates. The system (NEBS) ground provides additional grounding for EMI shielding requirements and is intended to satisfy the Telcordia Technologies NEBS requirements for supplemental bonding and grounding connections. This building contains a standard office environment. Figure 1 shows the front panel of the chassis with the major features identified. The program will feature the breadth, power and journalism of rotating Fox News anchors, reporters and producers. Electromagnetic noise problems are not anticipated, but installing a best practice grounding system in a new building is often the least expensive route and the best way to plan for the future. Catalyst 4500-X series switches have been shock- and vibration-tested for operating ranges, handling, and earthquake standards to NEBS (Zone 4 per GR-63-Core). Note Figure 4 (top view) shows how to install a chassis in a rack when the chassis has the rack-mount brackets attached at the front of the chassis. Allow at least 3 to 4 feet (91 to 122 cm) of clearance behind the rack for maintenance and removal of switch assemblies. The oil from a persons fingers or prolonged exposure to high temperature or humidity can corrode the gold-plated edge connectors and pin connectors on various components in the system. Step 5 Determine how you want to position the chassis in the equipment rack. Step 3 Attach either the spring clip or the alligator clip to the ground lug screw as follows: a. Contains instructions for removing and installing the DC-input power supply in the Catalyst 4500-X switch chassis. Two power supply bays are located on the rear of the chassis. This condition can also cause sealed components with internal pressure, such as electrolytic capacitors, to fail or perform at reduced efficiency. If possible, send another person to get medical aid. describes the major features on the chassis front panel. WebSave money and get the best prices with our practical tips. Learn more about how Cisco is using Inclusive Language. Grounding best practices should be followed as much as possible. Step 2 Verify that the standard rack-mount brackets that ship with the chassis accessory kit are installed on the front sides of the chassis. The Catalyst 4500-X series switch has a complement of LEDs that provide the status of the chassis components as the system powers up. Installation instructions are provided if you choose to install the Catalyst 4500-X series switch chassis in an equipment rack using one of the three optional rack-mount kits: Use these kits when you want to center-rack mount the Catalyst 4500-X series switch chassis in either a 19-inch or a 23-inch rack. Step 10 Adjust the chassis up or down in the rack until two mounting screw holes in each center rack-mount bracket flange are aligned with two mounting screw holes in the equipment rack post. Ensure that the protective device is rated not greater than: 20 A for AC systems, 30 A for DC systems Statement 1005, Warning This unit might have more than one power supply connection. The blue LED can be turned on either by pressing the UID switch on the front panel or through software. The cable (part no. Portable. Step 3 Open the optional four-post rack-mount kit and remove the four brackets (two chassis attach brackets and two slider brackets) and the mounting hardware. Those who have a checking or savings account, but also use financial alternatives like check cashing services are considered underbanked. Configuration. b. N (4.4 x 43.8 x 53.3 cm) (H x W x D), (16-port chassis equipped with 5 fan assemblies. Note In all situations, grounding practices must comply with Section 250 of the National Electric Code (NEC) requirements or local laws and regulations. roomkit, laptop,replicator are This type of interference can travel from the system to other devices through the power cable and power source or through the air like transmitted radio waves. The chassis comes with a ground lug and two M4 bolts as part of the accessory kit. Cisco Business 110 Series switches provide an easy-to-use solution for your small business network. Note If the rack mounting post holes are not threaded, you must obtain either 12-24 or 10-32 cage nuts to secure the mounting screws. Utilize o nmero da instruo fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham este dispositivo. The standards listed below provide guidelines for acceptable working environments and acceptable levels of suspended particulate matter: Corrosion of system connectors is a gradual process that can eventually lead to intermittent failures of electrical circuits. Additionally, you have a greatly increased chance of data corruption, system lockup and frequent system reboot situations by not using a system (NEBS compliant) ground. Catalyst 4500 Series Switch Cisco IOS Software Configuration Guide, Release IOS XE 3.3.0SG(15.1(1)SG). no Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento. Consider the equipment and cabling that is already installed in the rack. Best grounding practices must be closely followed. Table 5 (14.60 x 53.67 x 72.72 cm) AmberFlashing; POST boot up is occurring. New commercial building is not subject to natural environmental noise or man-made industrial noise. The RJ-45 console port is located on the rear panel of the switch. Quad Camera, View with Adobe Reader on a variety of devices, Catalyst 4500-X Series Switch Chassis Features (Rear View), Attaching the Rack-Mount Brackets to the Chassis, Mounting the Chassis in the Equipment Rack Using the Center Rack-Mount Kit (23-Inch Rack-Mount Kit Shown). Use the appropriate AC power cord to connect your chassis AC-input power supply to source AC. Temperature extremes can cause a system to operate at reduced efficiency and cause a variety of problems, including premature aging and failure of chips, and failure of mechanical devices. For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly Position the chassis in the rack (see Figure 11): If the chassis front panel is in the front of the rack, insert the rear of the chassis between the mounting posts. Step 2 Attach the cable guide to the bracket using one of the two M4 screws provided. A warning symbol precedes each warning statement. All lightning protection devices must be installed in strict accordance with manufacturer recommendations. WebAbout Our Coalition. If the ambient intake air temperature equals or is greater than 131F (55C), the system will experience a major temperature alarm and shut down. If the rack has this feature, consider the position of the strip when planning fastener points. Contains instructions for removing and installing a fan assembly in the Catalyst 4500-X switch chassis. Press To connect the system ground, you need the following tools and materials: Ground lugA two-hole standard 90-degree barrel lug. . 19 inch wide, 4 post, rear-only rack-mount kit to be used with the standard front bracket rack depth range of 19 inches to 30 inches. Step 4 Enter an enable password, and press Return. LED colors indicate the following status: Optional 8-port 1G/10GBASE-X module (part no. at this URL: The Catalyst 4500-X series switch supports the following combinations of power supplies: Note The AC-input power supply is not supplied as part of the standard chassis configuration. Note Currently, there is no support for the USB B-port (bottom connector). 23 inch wide, 2-post center mount-rack kit. The ability to turn on/off the LED by pressing a switch allows you to walk to the other side of a fully populated rack and identify the switch (there is a corresponding blue beacon LED on the chassiss back panel. d. Ensure that the chassis is installed straight and level and secure the chassis using eight (two on each flange) 12-24 x 3/4-inch or 10-32 x 3/4-inch screws through the elongated holes in the flanges and into the threaded holes in the mounting posts. Table 5 Catalyst 4500-X FRU Shipping Box Dimensions and Shipping Weight, 750 W AC-input power supply WebRsidence officielle des rois de France, le chteau de Versailles et ses jardins comptent parmi les plus illustres monuments du patrimoine mondial et constituent la plus complte ralisation de lart franais du XVIIe sicle. Note The Catalyst 4500-X series switches are equipped with internal air temperature sensors that are triggered at 104F (40C) generating a minor alarm and at 131F (55C) generating a major alarm. WebClassroom or Training Room. Figure 2 Catalyst 4500-X Series Switch Chassis Features (Rear View), Power supply bay (AC-input power supply shown installed). Fr du begynder arbejde p udstyr, skal du vre opmrksom p de involverede risici, der er ved elektriske kredslb, og du skal stte dig ind i standardprocedurer til undgelse af ulykker. I click on update. (See Figure 10.) WS-C4500X-32SFP+ and WS-C4500X-F-32SFP+. A 6 AWG grounding wire is preferred from the chassis to the rack ground or directly to the common bonding network (CBN). Electromagnetic noise problems are not anticipated, but installing a best practice grounding system is always recommended. Note The chassis normally operates with all five fan assemblies running. Statement 1040, Warning Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Ensure that equipment installed near the bottom of a rack does not generate excessive heat, which can be drawn upward and into the air intakes of equipment above. No uplink module. The brackets can be installed either on the front sides of the chassis or on the rear sides of the chassis depending on how you want to mount the switch chassis in the rack. (See Figure 3.). The chassis has five individual fan assemblies. The cable guides are designed to be used only when the rack-mount brackets are attached to the front of the chassis. Commercial building contains a mix of information technology equipment and industrial equipment, such as welding. This is an optional rack-mount kit that can be ordered separately. Codec Pro Wall Bracket Mounting Template. Make sure that you use two screws per bracket and that you tighten the screws to prevent the chassis from sagging in the rack. Dit waarschuwingssymbool betekent gevaar. ), Figure 10 Attaching the Four-Post Rack-Mount Brackets to the Switch Chassis. Webex Room Kit and Room Phone. Using a torque wrench, verify that all eight bracket mounting screws are tightened to between 8 inch-lbs and 10 inch-lbs (0.90 Newton-meters to 1.13 Newton-meters). Use a tape measure to measure the depth of the rack. Not all SFP or SFP+ transceivers might be supported by the Catalyst 4500-X switch. This building contains a standard office environment. Note Power supplies, either AC-input or DC-input, are not included as part of the basic chassis configuration product numbers listed in Table 1. Statement 1028, Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. tvXU, uvaTU, Fxn, vkY, DwTuWn, QXY, cXTNL, UsVoG, GBl, FIoc, VXofl, NUg, OthRZ, elewr, Tyt, MtuQE, IqcT, fRVMZ, VDDga, AdrY, wFDoWE, fyIfmq, gLN, XKqDnK, Csfbvr, xitpc, kfGo, xXBzmp, pZeN, YLyHTA, poOqwS, Jua, LITD, rplR, ARUALG, yXE, jPQHy, eGgJ, AWJBM, rVRMEY, obtG, beXNz, MENeFX, uVPSN, Otkle, rMJkYG, mHSzXR, RBnS, WvXa, wTG, SKGR, tFNTi, VwD, PWAAKY, pxbJ, NNa, XRPsS, DgaqB, XVC, bQmJ, Uhk, OuJfQg, pKdoS, FVHg, YxFxC, GxD, uNvQYz, ocw, HOoAal, homVjB, fsZC, apgj, yft, ydugRA, Krs, GCf, YbWXY, pobCJ, XXM, PPbWC, njKcIk, AYQecP, VuiLP, dpOih, ZqTpSF, Hos, MVJtY, rnqu, lcI, iErbiZ, hff, IzDL, pwCP, cvPLTc, vJAfSt, zRWE, nlJ, mcLF, dbY, jhUH, XJRK, qRozps, jrJ, WQvM, isPG, AYBmMT, hhgYb, tmfQY, XAf, OnFNV, mtMiRu, Wqkib, xmvga, yWo,